Barrier-free vertical cabinet type anti-static tester
Functional characteristics 1) Swipe to identify effective identities, static detection can avoid forced intrusion, and improve the overall anti-static effect. 2) The card swiping system can choose induction card recognition or fingerprint recognition, and the card recognition types include common EMID and Mifar...
Barrier-free vertical cabinet type anti-static tester
ESD access control system features
1) Swipe to identify effective identities, static detection can avoid forced intrusion, and improve the overall anti-static effect.
2) The card swipe system can choose induction card recognition or fingerprint recognition. The card recognition types include common EMID, Mifare, HID and other cards, and the original employee card can be used to realize the card pass.
3) Card permissions can be set to give different static detection options, such as VIPs or managers only need to swipe a valid card to pass; the detection permissions for anti-static detectors can be divided into 1) test wrist strap 2) test feet 3) Testing authority such as hand shoe testing.
4) The display screen is an 8-inch display color screen, which can display the test time, card number, work number, name, test results and photos, including various test information of static electricity detection.
5) Scientific information management, accurate and effective, 100% paperless records, ESD static detection host automatically log in to the test interface, and automatically generate complete ESD test management reports.
6) Real-time upload of detection data and real-time delivery of updated data to avoid data loss; if a network failure occurs, the detection data can be automatically saved to the network recovery and the saved data can be automatically uploaded to the server.
7) In case of network failure, the device supports long-term offline use, and the data storage space is 4GB when offline.
8) The software supports data export of entry report and exit report to provide a basis for personnel attendance.
9) The entire test panel of the electrostatic tester is designed to be waterproof and transparent to avoid and prevent the adverse effects of the external environment and extend the service life of the test instrument.
10) The test of the static tester is a touch type, which avoids the disadvantage that the traditional tester button type is easily damaged.
11) The static test resistance can be set according to customer requirements, the error of each set resistance is less than 5%, and the test speed is industry-leading.
Working principle of ESD access control system
After swiping the card, the employee gives an identification signal to the electrostatic controller to complete the test when touching the test button.
technical parameter
Power supply voltage: AC220V±10V, 50Hz
Working environment temperature: -40℃~60℃
Relative humidity: less than 95%, no condensation
Passing speed: 40 people/minute
Input interface: +12V level signal or DC12V pulse signal drive current with pulse width>100ms>10mA
Communication interface: RS485 or TCP/IP
The stable operation state of the equipment and the low power consumption design meet the requirements of energy saving and environmental protection.
With information storage function, can export employee ESD information
1. When employees test the static wristband OK, they are allowed to enter the workshop
2. When employees test the static shoes OK, they are allowed to enter the workshop (the left and right feet can be distinguished)
3. When employees test that both static shoes and static wrist straps are OK, they are allowed to enter the workshop
4. When the customer needs to enter the workshop, only need to swipe the VIP card, without detection, allowing to enter the workshop
5. When the internal management personnel need to enter the workshop, only need to swipe the test-free card.
The above five entry methods, we have correspondingly set five types of cards:
The first test for static shoes and wrist straps
The second type only needs to test the static shoes, only the shoe 2 card
The third type only needs to test the wrist band, only the wrist band 3 card
The fourth type of foreign VIP VIP free test card type 4 card
The fifth type of internal management personnel management personnel exemption card type 5 card
The company can set different test card permissions according to different test requirements.
ESD access control system operation process
1. Wear electrostatic clothes, electrostatic caps, electrostatic shoes, electrostatic wristbands and other related electrostatic protection products first.
2. Stand on both feet and the metal sheet of the foot pedal naturally. After swiping, touch your finger with the metal ring test button. When the PASS light of the currently tested item is on, the display will show that the test passed.
3. Don't be crowded when conducting static electricity inspection, keep a certain distance between people;
4. It is strictly forbidden not to read the card or detect it;
5. It is recommended to mark the instructions for the passage of the machine in a conspicuous place on the equipment and guide the passers-by to enter and exit in a safe and orderly manner;
6. The equipment should be properly managed when it is not working, and it is strictly prohibited to knock or shake the equipment;
7. When the device is turned off, it is strictly forbidden to push or pull or hit the cabinet cabinet.
Precautions
1. Please be familiar with the operation procedure of static electricity detection so as not to affect the passing speed.
2. The touch buttons have replaced the traditional test button buttons, and only need to be touched by your finger, without pressing hard; upgrading to the touch test button is more effective to improve the test effect.